ConceptWall 50 Structural Glazed
Technical informationPerformance
Comfort
- Air tightness
- A4
- Water tightness
- RE1200 (1200Pa)
- Wind load resistance
- 2000 Pa
- Acoustics - Rw(C;Ctr)
- 45(-2;-6) dB
Properties
Max. dimensions & weight
- Min. intertia mullion - Ix
- 13.5 cm4
- Max. intertia transom - Ix
- 534.7 cm4
- Min. intertia transom - Iy (glass load)
- 7.9 cm4
- Max. intertia transom - Iy (glass load)
- 59 cm4
Sightlines
- Min. width T-profile
- 1 15/16 inch
- Min. visible width (interior view)
- 1 15/16 inch
- Min. visible width (exterior view)
- 1 15/16 inch
- Min. depth mullion
- 1 5/8 inch
- Max. depth mullion
- 11 13/16 inch
- Min. depth transom
- 3/16 inch
Glazing
- Glazing method
- External glazing - Structural Glued Glazing - Structural Glued Stepped Glazing