Performance

Comfort

Air tightness
AE1200 (1200Pa)
Water tightness
RE1200 (1200Pa)
Wind load resistance
2000 Pa
Acoustics - Rw(C;Ctr)
47(-2;-5) dB

Safety

Burglar resistance
RC2 - RC3
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. intertia mullion - Ix
74 cm4
Max. intertia transom - Ix
937 cm4
Min. intertia transom - Iy (glass load)
23 cm4
Max. intertia transom - Iy (glass load)
68 cm4

Sightlines

Min. width T-profile
1 15/16 inch
Min. visible width (interior view)
1 15/16 inch
Min. visible width (exterior view)
1 15/16 inch
Min. depth mullion
3 5/16 inch
Max. depth mullion
9 1/16 inch
Min. depth transom
3 5/16 inch

Glazing

Glazing method
Dry glazing - Siliconized glazing - Pressure plate glazing