ConceptWall 60
Technical informationPerformance
Comfort
- CWCT tested according to
- Sequence B
- Air Leakage CWCT
- A4 (600Pa)
- Water Penetration CWCT
- R7 (600Pa)
- Wind Resistance (Serviceability) CWCT
- 2400 Pa
- Wind Resistance (Safety) CWCT
- 3600 Pa
Properties
Max. dimensions & weight
- Max. weight of glass
- 1653 lbs
- Min. intertia mullion - Ix
- 45 cm4
- Max. intertia mullion - Ix
- 1940 cm4
- Min. intertia transom - Ix
- 45 cm4
- Max. intertia transom - Ix
- 871 cm4
- Min. intertia transom - Iy (glass load)
- 33 cm4
- Max. intertia transom - Iy (glass load)
- 111 cm4
Sightlines
- Min. width T-profile
- 2 3/8 inch
- Min. visible width (interior view)
- 2 3/8 inch
- Min. visible width (exterior view)
- 2 3/8 inch
- Min. depth mullion
- 2 7/16 inch
- Max. depth mullion
- 9 7/8 inch
- Min. depth transom
- 2 5/8 inch
- Max. depth transom
- 8 7/16 inch
Glazing
- Glazing method
- Dry glazing - External glazing - Pressure plate glazing - Structural Glued Glazing - Structural clamped glazing