Skip to main content

ConceptWall 86

Technical information

Performance

Comfort

Air tightness
0.04 cfm/ft³
Water tightness
9 psf
Air tightness
AE 900 (900Pa)
Water tightness
RE1200 (1200 Pa)
Wind load resistance
Class B5 (2000Pa)
PG rating
105
Acoustics STC
39 dB
Acoustics OITC
32 dB

Safety

Burglar resistance
RC2
Impact resistance
I5/E5
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
19 11/16 inch
Max. height of vent
78 3/4 inch
Min. width of vent
19 11/16 inch
Max. width of vent
78 3/4 inch
Max. weight of vent
396 lbs
Max. weight of glass
661 lbs
Min. intertia mullion - Ix
13.85 cm4
Max. intertia mullion - Ix
544.25 cm4
Min. intertia transom - Ix
38.86 cm4
Max. intertia transom - Ix
435.83 cm4
Min. intertia transom - Iy (glass load)
51.54 cm4
Max. intertia transom - Iy (glass load)
153.38 cm4

Sightlines

Min. width T-profile
3 3/8 inch
Min. visible width (interior view)
3 3/8 inch
Min. visible width (exterior view)
3 3/8 inch
Min. depth mullion
1/4 inch
Max. depth mullion
4 3/4 inch
Min. depth transom
1 1/16 inch
Max. depth transom
5 11/16 inch

Glazing

Glazing method
Dry glazing - External glazing - Glazing bead - Structural Glued Glazing
Min. glass thickness - frame/element
1/4 inch
Max. glass thickness - frame/element
1 1/2 inch
Min. glass thickness - vent
1/4 inch
Max. glass thickness - vent
1 1/2 inch